ABSTRACT

Abstract This study aimed to evaluate the effect of the composite shade and distance from the light-curing unit (LCU) tip on the irradiance reaching the bottom of composite disks and on the depth of polymerization. Composites of three shades (opaque - OXDC, bleach - BXL, and A2) were inserted into molds with 3-mm of thickness positioned over a spectrometer and photo-activated with the LCU (Bluephase) tip placed at 0 or 1 cm from the composite surface. The mean irradiance reaching the bottom of composite was recorded during the entire photo-activation (30 s). Specimens (2 x 2 x 4 mm) were polymerized and used to map the degree of conversion achieved in different depths from irradiated surface. Specimens were sectioned into slices that were positioned over the platform of the infra-red microscope connected to the spectrometer to map the conversion. The conversion was measured in eight different depths every 500-µm. Increasing the distance of LCU tip reduced the irradiance only for A2. Interposing OXDC disks resulted in lowest values of irradiance and A2 the highest one. A tendency to decrease the conversion was observed towards the bottom of specimens for all experimental conditions, and the slope was more accentuated for OXDC. Differences among shades and distances from LCU tip were evident only beyond 1.5-2.0 mm of depth. In conclusion, both composite shade and distance from LCU tip might affect the light-transmission and depth of polymerization, while the effect of last was more pronounced.


Resumo Este estudo objetivou avaliar o efeito da cor do compósito e da distância da ponta do aparelho fotopolimerizador (AFP) na irradiância alcançando a base do disco de compósito e na profundidade de polimerização. Compósitos de três cores (opaca - OXDC, clareado - BXL, e A2) foram inseridos em moldes com 3 mm de espessura posicionados sobre um espectrômetro e fotoativados com a ponta do AFP (Bluephase) colocada a 0 ou 1 cm da superfície do compósito. A irradiância média alcançando a base do compósito foi registrada durante toda a fotoativação (30 s). Amostras (2 x 2 x 4 mm) de compósito polimerizado também foram confeccionadas e usada para mapear o grau de conversão obtido em diferentes profundidades da superfície irradiada. As amostras foram seccionadas em fatias que foram posicionadas sobre a plataforma de um microscópio infra-vermelho conectado ao espectrômetro para mapear a conversão. A conversão foi mensurada em oito diferentes profundidades com 500-µm entre elas. Aumentando a distância da ponta do AFP reduziu a irradiância apenas para A2. Interpondo discos de OXDC resultou em menores valores de irradiância e A2 nos maiores. Uma tendência de redução na conversão foi observada em direção a base das amostras para todas as condições experimentais, com uma redução mais acentuada para OXDC. Diferenças entre as cores e distâncias da ponta do AFP foram evidentes apenas a partir de 1,2-2,0 mm de profundidade. Como conclusão, tanto a cor do compósito como a distância da ponta do AFP podem afetar a transmissão de luz e a profundidade de polimerização, enquanto que o efeito do último foi mais pronunciado.


Subject(s)
Composite Resins/chemistry , Curing Lights, Dental , Surface Properties , In Vitro Techniques , Polymerization
2.
Braz. dent. j ; 26(2): 141-145, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-741215

ABSTRACT

Despite several advantages associated with pre-fabricated glass-fiber posts, the coronal portion of these posts must be cut to allow their use in various clinical situations. However, cutting the cemented post can generate stress on the bonding interface and affect the bond strength. The aim of this study was to investigate the effect the of fiber post cutting on the bond strength of root canals. Sixty bovine incisor roots were included in resin cylinders with simulated periodontal ligaments. Glass-fiber posts were luted using regular resin cement RelyX ARC (3M ESPE) or self-adhesive cement RelyX Unicem (3M ESPE). The posts were cut prior to cementation, immediately after luting or after building up the core (n=10). After storage for 24 h, the samples were cut and subject to push-out testing using a mechanical testing machine (EMIC DL 2000). Data were analyzed using two-way ANOVA (resin cement x moment of post cutting) and Tukey's post hoc test (α=0.05). The moment of fiber post cutting did not affect the bond strength when Unicem was used. However, the bond strength was reduced when ARC was used and when the post was cut immediately. In conclusion, the moment of fiber post cutting may affect the retention of root canal posts when a regular resin cement is used.


Apesar das diversas vantagens associadas aos pinos de fibra de vidro pré-fabricados, o corte da sua porção coronária deve ser realizado para permitir seu uso em algumas situações clínicas. Entretanto, o corte do pino cimentado pode gerar tensões na interface adesiva e afetar a resistência de união. O objetivo deste estudo foi avaliar o efeito do momento do corte do pino na resistência de união ao canal radicular. Sessenta raízes de incisivos bovinos foram incluídas em cilindros de resina com simulação do ligamento periodontal. Pinos de fibra de vidro foram cimentados utilizando um cimento resinoso convencional RelyX ARC (3M ESPE) ou autoadesivo RelyX Unicem (3M ESPE). Os pinos foram cortados previamente à cimentação, imediatamente após a cimentação, ou após a reconstrução do núcleo de preenchimento (n=10). Após o armazenamento por 24 h, as amostras foram seccionadas e submetidas ao ensaio de cisalhamento por extrusão utilizando máquina de ensaio mecânico (EMIC DL 2000). Os dados foram analisados por ANOVA dois fatores (cimento resinoso x momento do corte do pino) e teste de Tukey (=0,05). O momento do corte do pino de fibra de vidro não afetou a resistência de união quando o RelyX Unicem foi utilizado. No entanto, o corte do pino imediatamente após a cimentação reduziu os valores de resistência de união quando o RelyX ARC foi utilizado. Em conclusão, o momento do corte do pino pode afetar a resistência de união ao canal radicular quando o cimento resinoso convencional for utilizado.


Subject(s)
Animals , Cattle , Bisphenol A-Glycidyl Methacrylate/chemistry , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Post and Core Technique/instrumentation , Resin Cements/chemistry , Dental Bonding , Dental Stress Analysis , Dentin , Glass , In Vitro Techniques , Incisor
8.
Acta odontol. latinoam ; 23(2): 124-128, Sept. 2010. graf, tab
Article in English | LILACS | ID: biblio-949649

ABSTRACT

This study evaluated the sealing ability of gray MTA-Angelus mixed with propyleneglycol in furcal perforations using a bacterial leakage test. Furcal perforations were created in 30 human mandibular molars using a size 3 round bur. The samples were divided randomly into 2 experimental groups (n=10) according to the mixing agent. In G1, the MTA powder was mixed with propyleneglycol, while distilled water was used in G2. A 3:1 powder-liquid ratio was used for both groups. The MTA was placed in the perforation with an MTA carrier and condensed with hand pluggers. Nonrepaired (n=5) and totally sealed (n=5) perforations served as positive and negative controls, respectively. Bacterial leakage was assessed daily for 30 days in a double-chamber apparatus with Enterococcus faecalis. Data were analyzed using Fisher exact test (p<0.05) for three leakage periods: 1st to 10th day (P1); 11th to 20th day (P2); and 21st to 30th day (P3). The positive control presented leakage in all specimens within the first 24 hours, while no leakage was observed in the negative control during the experimental period. Leakage was observed in five (50%) of the 10 samples of the propyleneglycol group (G1) and seven (70%) of the distilled water group (G2) by the 20th day, without significant difference between the groups in periods P1 and P2 (p=0.137). The leakage was significantly lower for G1 than G2 in period P3 (50% versus 100%, respectively, p=0.016). In this single aerobic bacterial leakage method, the use of propyleneglycol as a vehicle for gray MTAAngelus increased its sealing ability in furcal perforations at the end of the 30-day experimental period.


Este estudo avaliou a capacidade de selamento do MTA-Angelus cinza manipulado com propilenoglicol em perfuracoes de furca usando um teste de infiltracao bacteriana. Perfuracoes de furca foram criadas em 30 molares inferiores usando uma broca esferica numero 3. As amostras foram divididas aleatoriamente em dois grupos experimentais (n=10) de acordo com o agente de manipulacao. Em G1, o po do MTA foi manipulado com propilenoglicol enquanto que a agua destilado foi utilizada no G2. A proporcao po-liquido de 3:1 foi usada para ambos os grupos. O MTA foi colocado na perfuracao com uma porta- MTA e condensado com condensadores manuais. Perfuracoes nao-reparadas (n=5) e totalmente impermeabilizadas (n=5) serviram como controle positivo e negativo, respectivamente. A infiltracao bacteriana foi verificada diariamente durante 30 dias em um aparato de dupla camara com Enterococcus faecalis. Os dados foram analisados pelo teste exato de Fisher (p<0,05) para tres periodos: 1o ao 10o dia (P1), 11o ao 20o dia (P2) e do 21o ao 30o dia (P3). O controle positivo apresentou infiltracao em todas as amostras nas primeiras 24 horas, enquanto nenhuma infiltracao foi observada no controle positivo durante o periodo experimental. Infiltracao foi observada em 5 (50%) das 10 amostras do grupo do propilenoglicol (G1) e 7 (70%) do grupo da agua destilada no 20o dia, sem diferenca significativa entre o grupos nos periodos P1 e P2 (p=0,0137). A infiltracao foi significantemente menor para G1 que para G2 no periodo P3 (50% versus 100%, respectivamente, p=0,016). Neste metodo de infiltracao de apenas uma bacteria aerobica, o uso do propilenoglicol como veiculo para o MTA-Angelus cinza aumentou sua capacidade de selamento em perfuracoes de furca no final do periodo experimental de 30 dias.


Subject(s)
Humans , Oxides/pharmacology , Pit and Fissure Sealants/pharmacology , Propylene Glycols/pharmacology , Root Canal Filling Materials/pharmacology , Bismuth/pharmacology , Dental Cements/pharmacology , Dental Leakage/microbiology , In Vitro Techniques , Silicates
9.
Acta odontol. latinoam ; 22(2): 118-122, Sept. 2009. tab
Article in English | LILACS | ID: biblio-973543

ABSTRACT

The aim of this study was to compare the sealing ability of white mineral trioxide aggregate (MTA) with that of other materials used as a cervical barrier during intracoronal bleaching. Thirty eight extracted teeth were endodontically treated and 3 mm of filling was removed to receive the barrier material: G1- Coltosol; G2 - Vidrion R; G3 - White MTA; G4-No barrier (negative control) and G5- Roots totally protected with three layers of cyanoacrylate (positive control). The 30% hydrogen peroxide associated with the sodium perborate was left in the pulp chamber for 24 h. The specimens were immersed in a test tube containing a solution of potassium chromate (yellow), which turns blue in the presence of hydrogen peroxide. Two calibrated evaluators scored according to color in the presence of the detecting solution (0 - unaltered color, 1 - light blue and 2 - dark blue). Data were analyzed by the Kruskall-Wallis test (p<0.05). The results showed no statistically significant differences between the experimental group G3 and positive control (G5). No statistically significant difference was observed between G1 and G3. However, a statistical difference was verified between G2 and G3. MTA presented higher sealing ability than Vidrion R and did not differ from the positive control. However, there was no difference between MTA and Coltosol.


O objetivo deste estudo foi comparar a capacidade de selamento do agregado trioxido mineral (MTA) branco com outros materiais usados como barreiras cervicais durante clareamento intra-coronario. Trinta e oito dentes extraidos foram endodonticamente tratados e 3 mm de obturacao foi removida para receber o material da barreira: G1- Coltosol; G2 - Vidrion R; G3 - MTA branco; G4-Nenhuma barreira (controle negativo) e G5- Raizes totalmente protegidas com tres camadas de cianocrilato (controle positivo). Peroxido de hidrogenio a 30% (PH) associado com perborato de sodio foi deixado na camara pulpar por 24 h. As amostras foram imersas em tubos de ensaio contendo uma solucao de cromato de potassio (amarela) que se torna azul na presenca de peroxido de hidrogenio. Dois avaliadores calibrados atribuiram escores de acordo com a cor obtida na solucao detectora (0 - cor inalterada, 1 - azul claro e 2 - azul escuro). Os dados foram analisados pelo teste de Kruskall-Wallis (p<0,05). Os resultados nao mostraram diferencas estatisticamente significantes entre o grupo experimental G3 e o controle positivo (G5). Nenhuma diferenca estatisticamente significante foi observada entre G1 e G3. Entretanto, diferenca estatistica foi verificada entre G2 e G3. MTA apresentou maior habilidade de selamento que o Vidrion R e nao diferiu do controle positivo. Entretanto, nao houve diferenca entre MTA e Cotosol.

SELECTION OF CITATIONS